Abstract

Objective: This ex-vivo study evaluated and compared the canal transportation of the prepared root canals and centering ratio maintained by Mtwo, Protaper and Twited Ni-Ti rotary files using Crown-Down technique.Materials and Method: Thirty non-carious extracted permanent human maxillary central incisors without any fracture and having Vertucci type I canal configuration were selected. The teeth were divided into 3 groups each group comprising of ten teeth. All the teeth were mounted on a wax block and pre instrumented canal CT Scan was performed. Access cavity preparation was done in group samples and canal was prepared using crown down technique by Mtwo, Protaper and Twisted NiTi Rotary file systems for the respective groups. Image analysis was done at 9 levels to access transportation and centricity ratio from pre and post instrumented CT scan images. The results showed that Software program determined the volume of pre and post instrumented canals.Results: The Canal transportation occurred least in root canals prepared by Twisted files, followed by canals prepared by Mtwo files and Protaper files. Centricity ratio was maintained the best in root canals prepared by twisted files.Conclusion: Within the parameters of this study, canals prepared by Twisted Files showed a well centered preparation and maintained the original shape of the root canal without any aberrations.Bangladesh Journal of Medical Science Vol.16(2) 2017 p.212-218

Highlights

  • Biomechanical preparation, is recognized as being one of the most important stages in root canal treatment.1,2It thoroughly cleans and shapes the canals by removing the vital or necrotic tissues.This is carried out by enlarging and shaping the canal to allow for adequate chemical debridement, while preserving the radicular anatomy.[3]

  • Inference:In the middle third, centricity ratio was maintained well with no significant difference in the root canals prepared by Twisted, Mtwo&Protaper files and least by stainless steel files

  • The present study evaluated and compared canal preparation using ProTaper, Mtwo and Twisted files rotary NiTi for canal transportation and centering ability assessed by Computerized tomography

Read more

Summary

Objective

This ex-vivo study evaluated and compared the canal transportation of the prepared root canals and centering ratio maintained by Mtwo, Protaper and Twited Ni-Ti rotary files using Crown-Down technique. Access cavity preparation was done in group samples and canal was prepared using crown down technique by Mtwo, Protaper and Twisted NiTi Rotary file systems for the respective groups. Image analysis was done at 9 levels to access transportation and centricity ratio from pre and post instrumented CT scan images. Results: The Canal transportation occurred least in root canals prepared by Twisted files, followed by canals prepared by Mtwo files and Protaper files. Conclusion: Within the parameters of this study, canals prepared by Twisted Files showed a well centered preparation and maintained the original shape of the root canal without any aberrations.

Introduction
Methodology
Discussion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.