Abstract

Aim:Aim of this in vitro study was to compare the tensile bond strength of UniFil Bond (GC America) vs iBond (Heraeus Kulzer) in conjunction with light cure composite resin (Venus, Heraeus Kulzer).Materials and MethodsSixty mandibular molars were taken and divided into 3 groups which were treated with UniFil Bond, iBond and no adhesive respectively. The tensile test was performed using an Instron machine.ResultsThe results showed that multibottle systems (UniFil Bond, i.e., two-step)performed 30% better as compared with single bottle systems (all-in-one, i.e., one-step bonding agents).Conclusion:It can be concluded that UniFil Bond (Multibottle system – 6thgeneration type I) performed better than iBond (Single Bottle system – 7th generation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.