Abstract

The demand for large quantities of highly potent human mesenchymal stromal cells (hMSCs) is growing given their therapeutic potential. To meet high production needs, suspension-based cell cultures using microcarriers are commonly used. Microcarriers are commonly made of or coated with extracellular matrix proteins or charged compounds to promote cell adhesion and proliferation. In this work, a simple method (draining filter) to perform layer by layer (LbL) assembly on microcarriers to create multilayers of heparin and collagen and further demonstrate that these multilayers have a positive effect on hMSC viability after 48h of culture was demonstrated. The draining filter method is evaluated against two other methods found in literature-centrifugation and fluidized bed, showing that the draining filter method can perform the surface modification with greater efficiency and with less materials and steps needed in the coating process.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.