A case study of long-term RO plant operation without chemical pretreatment
A case study of long-term RO plant operation without chemical pretreatment
- Research Article
- 10.31357/fesympo.v27.6648
- Feb 15, 2024
- Proceedings of International Forestry and Environment Symposium
Social wellbeing is strongly linked with economic feasibility when it needs to attain with the technological advancements. Installation of Reverse Osmosis (RO) water treatment plants have been considered as a promising solution to provide clean water for human consumption, especially in the areas where the CKDu (chronic kidney disease of unknown etiology) prevails. At present, over 2,000 RO treatment plants were installed in the dry zone of Sri Lanka, yet economic feasibility for operation and maintenance of RO plants has not been assessed so far. The present study was intended to identify economic feasibility of operation and maintenance of RO plants. Investigations were carried out in six community RO plants which provided drinking water for over 17,000 people which accounts for 20% of total population in Dimbulagala Divisional Secretariat over a period of 12 months. Six in-depth interviews and questionnaire survey were caried out with RO plant operators. The operational cost per production of cubic meter of filtered water was computed by considering electricity consumption bills. The maintenance costs and service charges were also obtained from the records available with RO plant operators. The results found that the average electricity consumption to produce 1 cube of filtered water is approximately 9kWh and cost is LKR 734 (based on 2021 rates). The average water selling price ranged between LKR 1.00-2.50 per liter. The average monthly income generation from one RO plant is approximately between LKR 561- 875 per cube of filtered water and it largely depended on the type of water source, climatic conditions. It was found that the income generated from RO plants was sufficient enough to cover the operation cost (monthly electricity bill) and for the subsequent maintenance and service charges whenever required. It can be concluded that the use of RO treated water is an economically viable option to provide portable drinking water. 
 Keywords: CKDu, Economic sustainability, Drinking water, Purification cost
- Research Article
- 10.5731/pdajpst.2017.008482
- Jan 1, 2018
- PDA Journal of Pharmaceutical Science and Technology
Recently, the use of filters has come into light for sanitizing water plants. This study investigated the role of heat-tolerant ultrafilters (UFs) for the remediation of reverse osmosis (RO) plants using periodic thermal disinfection. Two completely identical RO plants (RO plants A and B) were installed in 2006 for surgical hand antisepsis in the operating theater. RO water was stored in the 300 L storage tank and recirculated in the 190 meter-long loop delivering water to 12 faucets in each RO plant. Periodic thermal disinfection came into practice periodically when a UF module was retrofitted to the recirculation loop of each RO plant in 2010. Endotoxin was monitored closely before and after thermal disinfection. Before UF modules were retrofitted, endotoxin increased to a maximum of 0.301 EU/mL in RO plant A and 1.446 EU/mL in RO plant B after thermal disinfection, respectively. Since a UF module was retrofitted to each RO plant in 2010, endotoxin has been continuously below 0.025 EU/mL in RO plant A and exceeded this level five times in RO plant B. On one occasion, endotoxin increased in all samples collected simultaneously after solenoid valves were replaced in the recirculation loop near the air conditioner outlet. At this time, the inside of the pipework was exposed to the ventilation airflow. After the valves were replaced again, this time with the workplace isolated using a curing sheet, endotoxin decreased. On the other occasions, endotoxin increased only in one sample and decreased after thermal disinfection. Annually replaced UF modules were examined twice for estimating the amounts of immobilized endotoxin. The estimated amounts decreased in 2013 by the order of 10-3 in comparison with those in 2011 in both RO plants. The present study suggested that UFs acted synergistically with periodic thermal disinfection for the remediation of RO plants.
- Conference Article
- 10.1115/imece2012-85101
- Nov 9, 2012
In this paper, different strategies are investigated for the digital control of a reverse osmosis (RO) plant. Three control strategies to improve the performance of the RO plant are considered. These strategies including state-feeback, observer-based feedback and tracking control are considered. Simulation results show that the tracking controller yields the best perfoamnce, however it requires field knowledge about the RO plant operation. In this regard, observer-based feedback controller provides an alternative compromise.
- Research Article
- 10.56651/lqdtu.jst.v1.n01.632.pce
- Apr 27, 2023
- Journal of Science & Technique - Section of Special Construction Engineering
Seawater and brackish desalination using reverse osmosis (RO) has been a pragmatic approach to mitigating fresh water shortage in many water-stressed areas worldwide. Compared with other desalination technologies, RO has several attributes including high energy efficiency and system modularization. To achieve these notable attributes, for large-scale seawater RO plants, it is critical to accurately design and evaluate the RO process before plant installation and operation. In this study, the IMSDesign software is applied to design a seawater RO plant with a capacity of 100 m3 of fresh water per hour. The software allows to customize the design parameters and operating conditions of the RO plant to meet the design requirements. After inputting design parameters and operating conditions, the RO plant operation can be simulated to obtain its performance indexes for plant design evaluation. The evaluation results reveal that the RO plant with membrane trains arranged in 2-passes configuration can obtain high quality permeate that meets the required standards for drinking water at energy consumption and water cost of 10.66 kWh/m3 and 2.48 USD/m3, respectively.
- Supplementary Content
1
- 10.1080/19443994.2014.940645
- Sep 5, 2014
- Desalination and Water Treatment
Operational experience from hybrid RO system at SAFI wastewater re-use RO plant
- Research Article
22
- 10.1007/s13201-018-0821-8
- Sep 18, 2018
- Applied Water Science
Automation and reliability are the crucial elements of any advance reverse osmosis plant to meet the environmental and economic demands. Early fault indication, diagnosis and regular maintenance are the key challenges with most of the reverse osmosis plants in the Indian scenario. The present work introduces a modern reverse osmosis (RO) plant status monitoring unit to monitor different plant parameters in real time and early prediction for faults and maintenance. Developed RO plant status monitoring unit consists of a touch screen-based embedded monitoring unit, water quality sensors (pH, TDS), sampling chamber for controlled water flow, flow sensors, pressure and level sensors. The present system has been developed in a modular fashion so that it could be integrated with any capacity of RO plant units. Developed embedded system monitors various parameters of the plant such as input power, efficiency of the plant, level of input and output water tank and also guides operator with instructions for plant operation. Other than this, a dedicated smartphone app interface has been developed for the operator to acquire data from status monitoring unit, storage on smartphone, and transfer it to the cloud. The developed smartphone-based app also provides facility to integrate plant data with Google map with location information for easy understanding and quick action. The system has also a backup facility to transfer data to the server using 2G GSM module during the unavailability of the operator. A dedicated centralized Web server has been developed for real-time visualization of all installed RO plant status monitoring units. Different machine learning techniques have been implemented on acquired sensors data to predict early warnings related to power failure, membrane fouling and scaling, input water shortage, pipe, tank leakage, water quality sensors damage, non-operation or wrong operation of the plant along with different maintenance actions such as membrane water and chemical wash. Developed RO status monitoring unit has been tested with various RO plants having capacity from 500 LPH to 2000 LPH and deployed at various nearby villages of Rajasthan.
- Research Article
15
- 10.1007/s12199-016-0580-9
- Oct 15, 2016
- Environmental health and preventive medicine
Chronic Interstitial Nephritis in Agricultural Communities (CINAC) causes major morbidity and mortality for farmers in North-Central province (NCP) of Sri Lanka. To prevent the CINAC, reverse osmosis (RO) plants are established to purify the water and reduce the exposure to possible nephrotoxins through drinking water. We assessed RO plant maintenance and efficacy in NCP. We have interviewed 10 RO plant operators on plant establishment, maintenance, usage and funding. We also measured total dissolved solids (TDS in ppm) to assess the efficacy of the RO process. Most RO plants were operated by community-based organizations. They provide clean and sustainable water source for many in the NCP for a nominal fee, which tends to be variable. The RO plant operators carry out RO plant maintenance. However, maintenance procedures and quality management practices tend to vary from an operator to another. RO process itself has the ability to lower the TDS of the water. On average, RO process reduces the TDS to 29ppm. The RO process reduces the impurities in water available to many individuals within CINAC endemic regions. However, there variation in maintenance, quality management, and day-to-day care between operators can be a cause for concern. This variability can affect the quality of water produced by RO plant, its maintenance cost and lifespan. Thus, uniform regulation and training is needed to reduce cost of maintenance and increase the efficacy of RO plants.
- Research Article
6
- 10.3390/en14227739
- Nov 18, 2021
- Energies
This paper studies energy consumption management of seawater Reverse Osmosis (RO) desalination plants to maintain and enhance the Voltage Stability (VS) of Power Systems (PS) with Photovoltaic (PV) plant integration. We proposed a voltage-based management algorithm to determine the maximum power consumption for RO plants. The algorithm uses power flow study to determine the RO plant power consumption allowed within the voltage-permissible limits, considering the RO process constraints in order to maintain the desired fresh water supply. Three cases were studied for the proposed RO plant: typical operation with constant power consumption, controlled operation using ON/OFF scheduling of the High-Pressure Pumps (HPPs) and controlled operation using Variable Frequency Drive (VFD) control. A modified IEEE 30-bus system with a variable load was used as a case study with integration of three PV plants of 75 MWp total power capacity. The adopted 33.33 MW RO plant has a maximum capacity of 200,000 m3/day of fresh water production. The results reveal that while typical operation of RO plants can lead to voltage violation, applying the proposed load management algorithm can maintain the vs. of the PS. The total transmission power loss and power lines loading were also reduced. However, the study shows that applying VFD control is better than using ON/OFF control because the latter involves frequent starting up/shutting down the RO trains, which consequently requires flushing and cleaning procedures. Moreover, the specific energy consumption (SEC) and RO plant recover ratio decreases proportionally to the VFD output. Furthermore, the power consumption of the RO plant was optimized using the PSO technique to avoid unnecessary restriction of RO plant operation and water shortage likelihood.
- Single Report
5
- 10.2172/1597896
- Sep 1, 2019
The present study analyzes the economic viability of an Integrated Energy System (IES) that couples a Reverse Osmosis (RO) water desalination facility with a Nuclear Power Plant (NPP). The case study is conducted in collaboration with Arizona Public Service (APS), the operating owner of the Palo Verde Generating Station (PVGS) NPP. A challenge APS is facing is that their cooling water acquisition contract with the Sub Regional Operating Group (SROG) will expire soon and a renewal can only be done for a significantly higher price of the water. Therefore, APS is seeking alternative sources for their cooling water. One opportunity is to pump brackish water from the regional ground water. Although much less expensive than the water from the new SROG contract, the salinity of the brackish water is so high that a blend of brackish and SROG water will need additional treatment to improve its quality for use in the PVGS cooling towers. A study has been conducted in 2018 at Idaho National Laboratory (INL) to investigate the economics of an PVGS onsite RO desalination plant that would reduce the salinity of a SROG and brackish water blend to an acceptable level. One of the main findings of that study was that the overall economics of water desalination can be greatly improved if, in addition to cooling water for PVGS, potable water could also be produced and sold for profit. In fact, the study concluded that only producing cooling water for PVGS via RO desalination is not economically viable compared to buying all needed cooling water from the SROG. The present report investigates the economic impact of a large, regional RO desalination plant that could provide potable water for the region, considering the conclusions from last year’s scoping study. The study looks in particular at the water-market situation in the West Valley of Phoenix; i.e., in the area of the municipalities of Buckeye, Goodyear, Avondale and Tolleson. In addition to providing potable water for the adjacent municipalities, the concentrate from the regional RO plant would be taken and treated by PVGS to provide some cooling water for a (hopefully) lower cost than that of the SROG water. Furthermore, a cost structure could be put in place for the treatment of the concentrate from the regional RO that would offset some of the water acquisition cost for APS. The analysis used the Nuclear-Renewable Hybrid Energy System (N-R HES) software framework, which was developed at INL in 2016. The framework has reached some level of maturity, such that it can be applied to more than simple demonstration cases; i.e., real industry problems. The analysis in this report considers two cases (for various scenarios): First, the Base Case is the most economic one for APS, as no RO is built, i.e. the case for which cooling water acquisition and treatment cost are lowest. The 2018 INL study showed that some brackish water can be blended with the effluent SROG water without having to build the onsite RO. The Base Case is where APS pumps the maximum volume of less-expensive brackish water (limited by water chemistry in the cooling towers), blends it with the effluent from the SROG, and no RO is built. Second, the proposed RO Case includes two RO plants, one onsite at PVGS and another larger, regional one close to the brackish water wells. The regional RO produces potable water that is sold to the regional municipalities, while the PVGS RO onsite treats (part of) the regional ROs' concentrate and brackish water blend. The desalinated water from the PVGS RO is used in the cooling towers at PVGS. The analysis evaluates the difference in economics, using the Net Present Value (NPV) and Internal Rate of Return (IRR), between the cases. By comparing the two cases, in addition to evaluating the economics of the regional RO, we can also assess the impact of the regional RO on PVGS and consequently APS economics. The study shows that (for the Base Case) to offset the treatment cost for the RO concentrate, the cost of concentrate treatment to be paid by the regional RO to APS would be between 5 – 35 $/m3 of concentrate (depending on the regional RO size envisaged). Correspondingly, the Levelized Cost of Potable Water (LCOPW), which is the average or unit cost, for the regional RO is in the 0.55 – 0.6 $/m3 range of potable water. Or, considering the residential water demand model developed for the Phoenix West Valley, the NPV of the regional RO would be between $20 and 100 billion.
- Research Article
6
- 10.1016/s0011-9164(96)00087-2
- Aug 1, 1996
- Desalination
Design of a 1.4 mgd desalination plant based on MSF and RO processes for an arid area in India
- Research Article
- 10.1016/0011-9164(96)00087-2
- Aug 1, 1996
- Desalination
Design of a 1.4 mgd desalination plant based on MSF and RO processes for an arid area in India
- Research Article
38
- 10.1016/s0011-9164(03)00365-5
- Aug 1, 2003
- Desalination
Optimised desalination of seawater by a PV powered reverse osmosis plant for a decentralised coastal water supply
- Research Article
1
- 10.24949/njes.v6i1.37
- Dec 31, 2013
- SHILAP Revista de lepidopterología
In the past few years, the commercialization of small scale reverse osmosis (RO) plant for low total dissolved solids (TDS) brackish and contaminated groundwater water desalination offered an alternative solution to obtain drinking water with TDS lower than 500 mg/L. Due to rapid development in membrane technology the technical and economical usefulness of RO process has been improved. In the current research work, a prototype Reverse Osmosis (RO) wastewater treatmentplant has been developed and its performance was evaluated to produce the safe and drinkable water at local small community.Salt rejection and ermeatewater flowrate are the key performance parameters. These performance parameters are influenced by other variable parameters such as applied feed pressure, temperature, recovery and feed water salinity.The RO plant performance has been evaluated through testing different water quality parameters; including physical, chemical and biological analysis of the treated sample. The plant was operated by varying feed water pressures and feed water salinity which indicated that the product water has the highest quality and maximum permeateflow rate at 25 bar of applied feed water pressure for feed water salinity upto 4000 mg/L. The water quality results indicate that permeate obtained after treatment has excellent quality free physical and microbial contaminants.
- Research Article
42
- 10.1016/j.desal.2007.11.060
- Jan 9, 2009
- Desalination
Tandom reverse osmosis process for zero-liquid discharge
- Research Article
15
- 10.1504/ijnd.2003.003440
- Jan 1, 2003
- International Journal of Nuclear Desalination
The Nuclear Desalination Demonstration Project (NDDP) at Kalpakkam aims to demonstrate the safe and economic production of good quality water by desalination of seawater comprising 4,500 m³/d Multi-Stage Flash (MSF) and 1,800 m³/d Reverse Osmosis (RO) plant. The design of the hybrid MSF–RO plant to be set up at an existing nuclear power station is presented. The MSF plant based on long tube design requires less energy. The effect on performance of the MSF plant due to higher seawater intake temperature is marginal. The preheat RO system part of the hybrid plant uses reject cooling seawater from the MSF plant. This allows lower pressure operation, resulting in energy saving. The two qualities of water produced are usable for the power station as well as for drinking purposes with appropriate blending. The post treatment is also simplified due to blending of the products from MSF and RO plants. The hybrid plant has a number of advantages: part of high purity desalted water produced from the MSF plant will be used for the makeup demineralised water requirement (after necessary polishing) for the power station; blending of the product water from RO and MSF plants would provide requisite quality drinking water; and the RO plant will continue to be operated to provide water for drinking purposes during the shut down of the power station. Commissioning of the RO section is expected in 2002 and that of the MSF section in 2003. Useful design data are expected from the plant on the coupling of small and medium size reactors (SMR) based on PHWR. This will enable us to design a large size commercial plant up to 50,000 m³/d capacity. India will share the O&M experience of NDDP to member states of the International Atomic Energy Agency (IAEA) when the plant is commissioned. The development work for producing good quality water for power station from high salinity water utilizing low grade waste heat is presented. About 40 and 100 MWth low temperature waste heat is available in the moderator systems of the 220 and 500 MWe PHWR respectively. A significant part of this waste heat can be utilized for seawater desalination for in-house consumption. The Low Temperature Evaporation (LTE) technology for producing low conductivity water from seawater has been demonstrated at BARC on 30 m³/d scale by using waste heat. This plant is being connected to the CIRUS reactor for demonstration of coupling to a nuclear research reactor. The product water from this plant after minor polishing will meet the make up water requirement of the research reactor.