Abstract

Determining Caffeic acid is important as an antioxidant compound in food. In this study, caffeic acid (CA) was measured using a carbon paste electrode modified with GNR/CoFe2O4@NiO and 1-Ethyl-3-methylimidazolium acetate (EMIM Ac) as ion liquid. A simple sensor showed a higher current than a bare carbon paste; thus, it can be said that the modified electrode has a higher sensitivity for detecting CA. The linear range of this sensor and its detection limit was equal to 0.01–100.0 μM and 0.01 μM, respectively. Moreover, the developed electrode indicated outstanding selectivity in the presence of several interferences, high sensitivity, reproducibility, and long-term stability. The percentage recovery of CA obtained with the developed sensor affirmed its reliability for CA determination in real samples. The modified sensor's accuracy was confirmed to identify this analyte according to the results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.