Abstract

Transthoracic echocardiography (TTE) is recommended as the most important noninvasive screening tool for the diagnosis of pulmonary hypertension (PH), sonographers usually measure the volume of regurgitant flow rather than evaluating the spectral quality, so physicians will determine whether the ultrasound measurements of pulmonary arterial systolic pressure (US-PASP) are reliable based on the volume of tricuspid regurgitation (TR). Therefore, for the first time, we grade the quality of TR spectrum (TRS) based on its integrity and clarity, aiming to assess clinical application value of different tricuspid regurgitant spectrum quality grades (TR-SQG), and investigate whether the accuracy of US-PASP is more trustworthy than TR. We retrospectively analyzed 108 patients with chronic thromboembolic PH (CTEPH) to compare the correlation and agreement between US-PASP and right heart catheterization measurements of PASP (RHC-PASP). TR area (TRA) and TRS were measured in each patient, and TR-SQG was performed. The correlation coefficients between US-PASP and RHC-PASP were r=0.622 (P<0.001), r=0.754 (P<0.001), r=0.595 (P<0.001) in mild, moderate, severe TR, and r=0.301 (P=0.135), r=0.747 (P<0.001), r=0.739 (P<0.001), r=0.828 (P<0.001) in TR-SQG I-IV, respectively. Bland-Altman analysis revealed the mean biases of 5.05, 3.06, 7.62 mmHg in mild, moderate, severe TR, and -16.47, -8.07, 1.82, 6.09 mmHg in TR-SQG I-IV, respectively. In mild TR with the TR-SQG III and IV, the correlation coefficients between US-PASP and RHC-PASP were r=0.779 (P<0.001), intraclass correlation coefficient (ICC) =0.774, paired t-test P=0.160, respectively; and the consistency was significantly higher than that of mild TR without considering TR-SQG. In moderate TR with the TR-SQG III and IV, the r=0.749, ICC =0.746, paired t-test P=0.298 between US-PASP and RHC-PASP. The US-PASP with TR-SQG III or IV is trustworthy, and its accuracy and consistency are better than those predicted by the traditional severity of TR. The establishment of the ultrasound evaluation system of TR-SQG helps clinicians to judge whether the US-PASP is accurate, credible, and reliable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.