Abstract

ABSTRACT Aim: To present updated outcomes and toxicity data from patients with recurrent glioblastoma treated with the commercially available NovoTTF-100A System using patient registry database. Methods: The NovoTTF-100A device has been available by prescription at 126 oncology centers in the United States since November 2011. We retrospectively analyzed the outcomes and toxicity data from patients who were prescribed the device from November 2011 to November 2013 as treatment for recurrent glioblastoma. Overall survival (OS) was calculated based on social security death registry data. It was defined as the time from the treatment start until the date of death or last known date patient was alive. We analyzed performance status, compliance records, treatment history and adverse effects for all subjects. Results: There were 148 female and 309 male patients (n = 457) who were treated with NovoTTF-100A System. The median age was 55 years (range 18 to 86). Median Karnofsky Performance Status (KPS) was 80 (range 10-100) and 33% of patients were at their first recurrence when therapy was initiated. Over half of the patients (n = 252) received bevacizumab prior to NovoTTF- 100A therapy. The median OS was 9.6 (95% [CI] 8.0 to 13.7) months and the median treatment duration was 4.1 (95% [CI] 3.5 to 4.8) months. The average patient compliance with the use of the device was 70%. OS was positively correlated with higher compliance (= > 75%) and KPS (70-100), and negatively correlated with recurrence number and prior use of bevacizumab. Debulking surgery prior to the introduction of NovoTTF-100A therapy did not influence OS. The most common device-related adverse events included skin reactions (24.3%), neurological disorders (10.4%), heat sensation (8.9%), electric sensation (7.7%) and headache (5.7%). Conclusions: Treatment with NovoTTF-100A System, as prescribed in the neuro-oncology clinical practice to patients with recurrent glioblastoma offers favorable outcomes when compared to historical data. Patient compliance with the prescribed use of the system is high and positively correlates with improved survival. Bevacizumab naive patients benefit more while patients with poor KPS and multiple prior recurrences benefit less from this treatment. NovoTTF-100A System is well tolerated and has no new unexpected toxicities since its introduction to clinical practice. Disclosure: M.M. Mrugala: On Advisory Board of Novocure. PI on the clinical trial sponsored by Novocure; H.H. Engelhard: I have participated in Novocure's Advisory Boards; N. Butowski: I participated in Novocure's Advisory Board; D.D. Tran: I have received honorarium from Novocure for advisory board and speaker bureau; Y. Kew: I have participated in Novocure's Advisory Boards; R. Cavaliere: I have been a consultant for Novocure; J. Villano: Member of a speakers bureau and served on an advisory board for Novocure. D. Bota: Novocure Advisory Board; S. Kesari: I have received funding for advisory board meetings and clinical trials sponsored by Novocure; J. Rudnick: I have been a consultant for Novocure; A. Sumrall: I have been a Faculty Speaker and participated in an Advisory Board for Novocure; J.J. Zhu: Novocure Advisory Board; E.T. Wong: I received research funding from Novocure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.