3D printed dummy heads for crosstalk cancellation studies in bone conduction.

  • Abstract
  • Literature Map
  • Similar Papers
Abstract
Translate article icon Translate Article Star icon

Thanks to affordable 3D printers, creating complex designs like anatomically accurate dummy heads is now accessible. This study introduces dummy heads with 3D-printed skulls and silicone skins to explore crosstalk cancellation in bone conduction (BC). Crosstalk occurs when BC sounds from a transducer on one side of the head reach the cochlea on the opposite side. This can disrupt binaural cues essential for sound localization and speech understanding in noise for individuals using BC hearing devices. We provide a step-by-step guide to constructing the dummy head and demonstrate its application in canceling crosstalk. The 3D models used in this study are freely available for replication and further research. Several dummy heads were 3D-printed using ABS for the skull and silicone skins of varying hardness, with a 3-axis accelerometer at the cochlea location to simulate inner ear response. Since the cochlea is inaccessible in humans, we targeted crosstalk cancellation at the mastoid, assessing if this cancellation extended to the cochlea within the dummy heads. We compared these results with our previous experiments conducted on seven human subjects, who had their hearing thresholds measured with and without crosstalk cancellation, to evaluate if the dummy heads could reliably replicate human crosstalk cancellation effects.

Similar Papers
  • Book Chapter
  • 10.1016/b978-0-12-415994-5.00006-3
Chapter 6 - Speech Understanding in Noise
  • Oct 15, 2013
  • Noise and the Brain
  • Jos J Eggermont

Chapter 6 - Speech Understanding in Noise

  • Book Chapter
  • Cite Count Icon 28
  • 10.1159/000323585
Audiological Results with Baha<sup>®</sup> in Conductive and Mixed Hearing Loss
  • Jan 1, 2011
  • Flurin Pfiffner + 2 more

The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.

  • Research Article
  • Cite Count Icon 19
  • 10.1080/14670100.2019.1664529
Microphone directionality and wind noise reduction enhance speech perception in users of the MED-EL SONNET audio processor
  • Sep 16, 2019
  • Cochlear Implants International
  • Rudolf Hagen + 8 more

Objectives: Speech understanding in noise remains a challenge for many cochlear implant users. To improve this, the SONNET audio processor features three microphone directionality (MD) settings and three wind noise reduction (WNR) settings. The primary aim of this study was to assess if speech understanding in noise and hearing in real life was superior with the SONNET or with the OPUS 2, which does not feature MD or WNR.Methods: 31 of 33 participants completed the study. Speech understanding was assessed in two types of acoustic noise, in wind noise, and in quiet. A 4-speaker setup was used and speech was presented from 0° and noise from 90°, 180°, and 270°. Wind noise was simulated with a fan. Sound quality and hearing-related abilities were assessed via two subjective questionnaires.Results: Speech understanding in acoustic noise with the SONNET was significantly better or equal to than with the OPUS 2. Speech understanding in wind with the OPUS 2 was significantly better than with the SONNET in some settings. Sound quality and hearing-related abilities were both significantly better with the SONNET.Conclusions: The SONNET provides the same or significantly improved speech understanding than the OPUS 2 in quiet and in noise. While OPUS 2 was superior in wind than the SONNET in some settings, this was offset by SONNET's superiority in real-life listening situations. We therefore conclude that the front-end processing of the SONNET provides users with better hearing than does the OPUS 2.

  • Research Article
  • Cite Count Icon 3
  • 10.3109/17549507.2014.979875
Development of Trivia Game for speech understanding in background noise
  • Nov 24, 2014
  • International Journal of Speech-Language Pathology
  • Kathryn Schwartz + 4 more

Purpose: Listening in noise is an everyday activity and poses a challenge for many people. To improve the ability to understand speech in noise, a computerized auditory rehabilitation game was developed. In Trivia Game players are challenged to answer trivia questions spoken aloud. As players progress through the game, the level of background noise increases. A study using Trivia Game was conducted as a proof-of-concept investigation in healthy participants.Method: College students with normal hearing were randomly assigned to a control (n = 13) or a treatment (n = 14) group. Treatment participants played Trivia Game 12 times over a 4-week period. All participants completed objective (auditory-only and audiovisual formats) and subjective listening in noise measures at baseline and 4 weeks later.Result: There were no statistical differences between the groups at baseline. At post-test, the treatment group significantly improved their overall speech understanding in noise in the audiovisual condition and reported significant benefits in their functional listening abilities.Conclusion: Playing Trivia Game improved speech understanding in noise in healthy listeners. Significant findings for the audiovisual condition suggest that participants improved face-reading abilities. Trivia Game may be a platform for investigating changes in speech understanding in individuals with sensory, linguistic and cognitive impairments.

  • Research Article
  • Cite Count Icon 223
  • 10.3766/jaaa.22.3.4
Working Memory Supports Listening in Noise for Persons with Hearing Impairment
  • Mar 1, 2011
  • Journal of the American Academy of Audiology
  • Mary Rudner + 2 more

Previous studies have demonstrated a relation between cognitive capacity, in particular working memory, and the ability to understand speech in noise with different types of hearing aid signal processing. The present study investigates the relation between working memory capacity and the speech recognition performance of persons with hearing impairment under both aided and unaided conditions, following a period of familiarization to both fast- and slow-acting compression settings in the participants' own hearing aids. Speech recognition was tested in modulated and steady state noise with fast and slow compression release settings (for aided conditions) with each of two materials. Working memory capacity was also measured. Thirty experienced hearing aid users with a mean age of 70 yr (SD = 7.8) and pure-tone average hearing threshold across the frequencies 0.25, 0.5, 1, 2, 3, 4, and 6 kHz (PTA7) and for both ears of 45.8 dB HL (SD = 6.6. 9 wk experience with each of fast-acting and slow-acting compression. Speech recognition data were analyzed using repeated measures analysis of variance with the within-subjects factors of material (high constraint, low constraint), noise type (steady state, modulated), and compression (fast, slow), and the between-subjects factor working memory capacity (high, low). With high constraint material, there were three-way interactions including noise type and working memory as well as compression, in aided conditions, and performance level, in unaided conditions, but no effects of either working memory or compression with low constraint material. Investigation of simple main effects showed a significant effect of working memory during speech recognition under conditions of both "high degradation" (modulated noise, fast-acting compression, low signal-to-noise ratio [SNR]) and "low degradation" (steady state noise, slow-acting compression, high SNR). The finding of superior performance of persons with high working memory capacity in modulated noise with fast-acting compression agrees with findings of previous studies including a familiarization period of at least 9 wk, in contrast to studies with familiarization of 4 wk or less that have shown that persons with lower cognitive capacity may benefit from slow-acting compression. Working memory is a crucial factor in speech understanding in noise for persons with hearing impairment, irrespective of whether hearing is aided or unaided. Working memory supports speech understanding in noise under conditions of both "high degradation" and "low degradation." A subcomponent view of working memory may contribute to our understanding of these phenomena. The effect of cognition on speech understanding in modulated noise with fast-acting compression may only pertain after a period of 4-9 wk of familiarization and that prior to such a period, persons with lower cognitive capacity may benefit more from slow-acting compression.

  • Research Article
  • Cite Count Icon 5
  • 10.1044/1092-4388(2011/09-0268)
On the Use of the Distortion-Sensitivity Approach in Examining the Role of Linguistic Abilities in Speech Understanding in Noise
  • Dec 1, 2011
  • Journal of Speech, Language, and Hearing Research
  • S Theo Goverts + 4 more

Researchers have used the distortion-sensitivity approach in the psychoacoustical domain to investigate the role of auditory processing abilities in speech perception in noise (van Schijndel, Houtgast, & Festen, 2001; Goverts & Houtgast, 2010). In this study, the authors examined the potential applicability of the distortion-sensitivity approach for investigating the role of linguistic abilities in speech understanding in noise. The authors applied the distortion-sensitivity approach by measuring the processing of visually presented masked text in a condition with manipulated syntactic, lexical, and semantic cues and while using the Text Reception Threshold (George et al., 2007; Kramer, Zekveld, & Houtgast, 2009; Zekveld, George, Kramer, Goverts, & Houtgast, 2007) method. Two groups that differed in linguistic abilities were studied: 13 native and 10 non-native speakers of Dutch, all typically hearing university students. As expected, the non-native subjects showed substantially reduced performance. The results of the distortion-sensitivity approach yielded differentiated results on the use of specific linguistic cues in the 2 groups. The results show the potential value of the distortion-sensitivity approach in studying the role of linguistic abilities in speech understanding in noise of individuals with hearing impairment.

  • Book Chapter
  • Cite Count Icon 1
  • 10.1007/978-3-540-89208-3_385
Improving Speech Understanding in Noise for Users of Bone Anchored Hearing Aids (BAHA)
  • Jan 1, 2009
  • F Pfiffner + 2 more

Bone anchored hearing aids (BAHA) propagate sound via bone conduction through a retroaurically implanted screw. It is a successful method of treatment for middle ear pathologies. Nevertheless, speech understanding in noise is often limited. To our knowledge, increasing the high frequency response, known to contribute particularly to speech understanding in noise, has not been investigated and is not implemented in current BAHA devices. This investigation aims to begin to close this gap.

  • Research Article
  • Cite Count Icon 10
  • 10.1007/s00405-023-08149-9
Performance of an active transcutaneous bone conduction implant, the Osia system, in high frequencies and hearing in noise in users converted from a Baha attract system: a prospective study.
  • Aug 14, 2023
  • European Archives of Oto-Rhino-Laryngology
  • Jérôme Nevoux + 4 more

Hearing rehabilitation through middle ear surgery can be challenging, particularly for patients with chronic otitis media, but new hearing devices offer opportunity to reach this goal. The aim was to compare hearing outcomes and quality of life in patients who were converted from a Baha Attract system to the Osia system. Prospective observational study, in which each subject acted as their own control. Six patients who were converted from a Baha Attract to an Osia system performed audiometric and quality of life assessments with different sound processor at fitting, 3, 6 and 12months. The speech performance in noise with the Osia system at 12months, expressed as dB SNR, was compared to the baseline condition (Baha 5). The PTA4 hearing thresholds improved from 42.6 ± 11 with Baha 5 Power to 34.8 ± 13.3 with Baha 5 SuperPower and to 25.4 ± 3.5 with the Osia at 12months, leading to a significant functional gain of 17.2 ± 10.9dB vs Baha 5 (p < 0.02). Speech understanding in both quiet and noise was clinically improved reaching a mean SNR of less than 1dB at 12months with the Osia system. Quality of life outcomes improved by more than 20% at 12-month follow-up. Aided hearing thresholds and speech understanding in noise improved when patients were converted from the Baha Attract system to the Osia system. The aided hearing threshold was maintained up to 8kHz (26dB) with the Osia system.

  • PDF Download Icon
  • Research Article
  • Cite Count Icon 1
  • 10.1155/2021/1518385
Influence of Compression Thresholds and Maximum Power Output on Speech Understanding with Bone-Anchored Hearing Systems
  • Jan 1, 2021
  • BioMed Research International
  • Tom Gawliczek + 3 more

Bone-anchored hearing systems (BAHS) transmit sound via osseointegrated implants behind the ear. They are used to treat patients with conductive or mixed hearing loss, but speech understanding may be limited especially in users with substantial additional cochlear hearing losses. In recent years, BAHS with higher maximum power output (MPO) and more advanced digital processing including loudness compression have become available. These features may be useful to increase speech understanding in users with mixed hearing loss. We have tested the effect of 4 combinations of two different MPO levels (highest level available and level reduced by 12 dB) and two different compression thresholds (CT) levels (50 dB and 65 dB sound pressure level) in 12 adult BAHS users on speech understanding in quiet and in noise. We have found that speech understanding in quiet was not influenced significantly by any of the changes in these two fitting parameters. In contrast, in users with average bone-conduction (BC) threshold of 25 dB or more, speech understanding in noise was improved by +0.8 dB to +1.1 dB (p < 0.03) when using the higher MPO level. In this user group, there may be an additional, but very small benefit of +0.1 dB to +0.4 dB when using the lower rather than the higher CT value, but the difference was not statistically significant (p > 0.27). In users with better average BC thresholds than 25 dB, none of the improvement was statistically significant. Higher MPOs and possibly, to a lesser degree, lower CTs seem to be able to improve speech understanding in noise in users with higher BC thresholds, but even their combined effect seems to be limited.

  • Research Article
  • Cite Count Icon 57
  • 10.1001/jamaoto.2020.1584
Assessment of Speech Understanding After Cochlear Implantation in Adult Hearing Aid Users
  • Aug 27, 2020
  • JAMA Otolaryngology–Head &amp; Neck Surgery
  • Craig A Buchman + 6 more

Cochlear implants were approved for use in adults in the 1980s, but use remains low owing to a lack of awareness regarding cochlear implantation candidacy criteria and expected outcomes. There have been limited, small series examining the safety and effectiveness of cochlear implantation in adult hearing aid (HA) users with and without mild cognitive impairment (MCI). To investigate the safety and effectiveness of a single-ear cochlear implant in a group of optimized adult HA users with and without MCI across a variety of domains. In this nonrandomized controlled trial, a multicenter, prospective, repeated-measures investigation was conducted at 13 US institutions. The setting was academic and community-based cochlear implant programs. Eligible participants were 100 adults (aged >18 years) with postlinguistic onset of bilateral moderate sloping to profound or worse sensorineural hearing loss (≤20 years' duration). Fluent English speakers underwent an optimized bilateral HA trial for at least 30 days. Individuals with aided Consonant-Vowel Nucleus-Consonant (CNC) word score in quiet of 40% or less correct in the ear to be implanted and 50% or less correct in the contralateral ear were offered cochlear implants. The first participant was enrolled on February 20, 2017, and the last participant was enrolled on May 3, 2018. The final follow-up was on December 21, 2018. Participants received the same cochlear implant system and contralateral HA. The primary outcome measure was speech understanding in quiet (CNC word score) using both the cochlear implant and opposite ear HA. Secondary outcome measures included the following: adverse events; speech understanding in noise (AzBio signal-to-noise ratio of +10 db [+10 SNR]) Health Utilities Index Mark 3 (HUI3); Speech, Spatial, and Qualities of Hearing Questionnaire 49 (SSQ49); and Montreal Cognitive Assessment (MoCA). The median age at cochlear implantation of the 96 patients included in the trial was 71 years (range, 23-91 years), and 62 patients (65%) were male. Three serious adverse events requiring revision surgery occurred, and all resolved without sequelae. By 6 months after activation, the absolute marginal mean change in CNC word score and AzBio +10 SNR was 40.5% (95% CI, 35.9%-45.0%) and 24.1% (95% CI, 18.9%-29.4%), respectively. Ninety-one percent (87 of 96) of participants had a clinically important improvement (>15%) in the CNC word score in the implant ear. Mild cognitive impairment (MoCA total score ≤25) was observed in 48 of 81 study participants (59%) at baseline. Speech perception marginal mean improvements were similar between individuals with and without baseline MCI, with values of 40.9% (95% CI, 35.2%-46.6%) and 39.6% (95% CI, 31.8%-47.4%), respectively, for CNC word score and 27.5% (95% CI, 21.0%-33.9%) and 17.8% (95% CI, 9.0%-26.6%), respectively, for AzBio +10 SNR. Statistically significant and clinically important improvements in the HUI3 and SSQ49 were evident at 6 months. The findings of this nonrandomized controlled trial seem to indicate that cochlear implants are safe and effective in restoring speech understanding in both quiet and noise and improve quality of life in individuals with and without MCI. ClinicalTrials.gov Identifier: NCT03007472.

  • Research Article
  • Cite Count Icon 55
  • 10.1097/aud.0000000000000260
Matching Automatic Gain Control Across Devices in Bimodal Cochlear Implant Users.
  • May 1, 2016
  • Ear &amp; Hearing
  • Lidwien C E Veugen + 4 more

The purpose of this study was to improve bimodal benefit in listeners using a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, by matching the time constants and the number of compression channels of the automatic gain control (AGC) of the HA to the CI. Equivalent AGC was hypothesized to support a balanced loudness for dynamically changing signals like speech and improve bimodal benefit for speech understanding in quiet and with noise presented from the side(s) at 90 degree. Fifteen subjects participated in the study, all using the same Advanced Bionics Harmony CI processor and HA (Phonak Naida S IX UP). In a 3-visit crossover design with 4 weeks between sessions, performance was measured using a HA with a standard AGC (syllabic multichannel compression with 1 ms attack time and 50 ms release time) or an AGC that was adjusted to match that of the CI processor (dual AGC broadband compression, 3 and 240 msec attack time, 80 and 1500 msec release time). In all devices, the AGC was activated above the threshold of 63 dB SPL. The authors balanced loudness across the devices for soft and loud input sounds in 3 frequency bands (0 to 548, 548 to 1000, and >1000 Hz). Speech understanding was tested in free field in quiet and in noise for three spatial speaker configurations, with target speech always presented from the front. Single-talker noise was either presented from the CI side or the HA side, or uncorrelated stationary speech-weighted noise or single-talker noise was presented from both sides. Questionnaires were administered to assess differences in perception between the two bimodal fittings. Significant bimodal benefit over the CI alone was only found for the AGC-matched HA for the speech tests with single-talker noise. Compared with the standard HA, matched AGC characteristics significantly improved speech understanding in single-talker noise by 1.9 dB when noise was presented from the HA side. AGC matching increased bimodal benefit insignificantly by 0.6 dB when noise was presented from the CI implanted side, or by 0.8 (single-talker noise) and 1.1 dB (stationary noise) in the more complex configurations with two simultaneous maskers from both sides. In questionnaires, subjects rated the AGC-matched HA higher than the standard HA for understanding of one person in quiet and in noise, and for the quality of sounds. Listening to a slightly raised voice, subjects indicated increased listening comfort with matched AGCs. At the end of the study, 9 of 15 subjects preferred to take home the AGC-matched HA, 1 preferred the standard HA and 5 subjects had no preference. For bimodal listening, the AGC-matched HA outperformed the standard HA in speech understanding in noise tasks using a single competing talker and it was favored in questionnaires and in a subjective preference test. When noise was presented from the HA side, AGC matching resulted in a 1.9 dB SNR additional benefit, even though the HA was at the least favorable SNR side in this speaker configuration. Our results possibly suggest better binaural processing for matched AGCs.

  • Research Article
  • Cite Count Icon 14
  • 10.1007/s00405-013-2565-2
Influence of directionality and maximal power output on speech understanding with bone anchored hearing implants in single sided deafness
  • May 23, 2013
  • European Archives of Oto-Rhino-Laryngology
  • Silvia Krempaska + 5 more

Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8dB (p=0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8dB, if the directional microphone system was activated (p=0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.

  • Research Article
  • Cite Count Icon 100
  • 10.1097/aud.0b013e31820fc821
Digit Training in Noise Can Improve Cochlear Implant Users' Speech Understanding in Noise
  • Sep 1, 2011
  • Ear &amp; Hearing
  • Sandra I Oba + 2 more

While auditory training in quiet has been shown to improve cochlear implant (CI) users' speech understanding in quiet, it is unclear whether training in noise will benefit speech understanding in noise. The present study investigated whether auditory training could improve CI users' speech recognition in noise and whether training with familiar stimuli in an easy listening task (closed-set digit recognition) would improve recognition of unfamiliar stimuli in a more difficult task (open-set sentence recognition). CI users' speech understanding in noise was assessed before, during, and after auditory training with a closed-set recognition task (digits identification) in speech babble. Before training was begun, recognition of digits, Hearing in Noise Test (HINT) sentences, and IEEE sentences presented in steady speech-shaped noise or multitalker speech babble was repeatedly measured to establish a stable estimate of baseline performance. After completing baseline measures, participants trained at home on their personal computers using custom software for approximately 30 mins/day, 5 days/wk, for 4 wks, for a total of 10 hrs of training. Participants were trained only to identify random sequences of three digits presented in speech babble, using a closed-set task. During training, the signal-to-noise ratio was adjusted according to subject performance; auditory and visual feedback was provided. Recognition of digits, HINT sentences, and IEEE sentences in steady noise and speech babble was remeasured after the second and fourth week of training. Training was stopped after the fourth week, and subjects returned to the laboratory 1 mo later for follow-up testing to see whether any training benefits had been retained. Mean results showed that the digit training in babble significantly improved digit recognition in babble (which was trained) and in steady noise (which was not trained). The training benefit generalized to improved HINT and IEEE sentence recognition in both types of noise. Training benefits were largely retained in follow-up measures made 1 mo after training was stopped. The results demonstrated that auditory training in noise significantly improved CI users' speech performance in noise, and that training with simple stimuli using an easy closed-set listening task improved performance with difficult stimuli and a difficult open-set listening task.

  • Research Article
  • Cite Count Icon 9
  • 10.1016/j.anl.2020.05.025
The effects of behind-the-ear and off-the-ear sound processors on speech understanding performance in cochlear implant users
  • Jun 24, 2020
  • Auris Nasus Larynx
  • Merve Bayri + 1 more

The effects of behind-the-ear and off-the-ear sound processors on speech understanding performance in cochlear implant users

  • Research Article
  • Cite Count Icon 15
  • 10.1097/aud.0000000000000753
The Association Between Physiological Noise Levels and Speech Understanding in Noise.
  • Jan 1, 2020
  • Ear &amp; Hearing
  • Samantha Stiepan + 4 more

Traditionally, elevated hearing thresholds have been considered to be the main contributors to difficulty understanding speech in noise; yet, patients will often report difficulties with speech understanding in noise despite having audiometrically normal hearing. The purpose of this cross-sectional study was to critically evaluate the relationship of various metrics of auditory function (behavioral thresholds and otoacoustic emissions) on speech understanding in noise in a large sample of audiometrically normal-hearing individuals. Behavioral hearing thresholds, distortion product otoacoustic emission (DPOAE) levels, stimulus-frequency otoacoustic emission levels, and physiological noise (quantified using OAE noise floors) were measured from 921 individuals between 10 and 68 years of age with normal pure-tone averages. The quick speech-in-noise (QuickSIN) test outcome, quantified as the signal-to-noise ratio (SNR) loss, was used as the metric of speech understanding in noise. Principle component analysis (PCA) and linear regression modeling were used to evaluate the relationship between the measures of auditory function and speech in noise performance. Over 25% of participants exhibited mild or worse degree of SNR loss. PCA revealed DPOAE levels at 12.5 to 16 kHz to be significantly correlated with the variation in QuickSIN scores, although correlations were weak (R = 0.017). Out of all the metrics evaluated, higher levels of self-generated physiological noise accounted for the most variance in QuickSIN performance (R = 0.077). Higher levels of physiological noise were associated with worse QuickSIN performance in listeners with normal hearing sensitivity. We propose that elevated physiological noise levels in poorer speech in noise performers could diminish the effective SNR, thereby negatively impacting performance as seen by poorer QuickSIN scores.

Save Icon
Up Arrow
Open/Close
Notes

Save Important notes in documents

Highlight text to save as a note, or write notes directly

You can also access these Documents in Paperpal, our AI writing tool

Powered by our AI Writing Assistant