Abstract

Ultrasonic Doppler method for flow metering system has been developed. The principle is based on the integration of instantaneous velocity profile over a pipe diameter so that it is expected to be able to eliminate installation problems such as entry length as well as to follow transient flow rate precisely. Therefore, in the present study, we reported the results of multiline flow rate measurement employing this method Flow metering principle by ultrasonic Doppler method in a circular pipe depends on the alignment of measuring lines. And in most cases, metallic pipes are used both in industrial factories and power plants. In this paper, the influence of the number of measuring lines and the comparison among several kinds of metallic pipes on the flow rate measurements have been investigated for nondeveloped flows in a vertical pipe.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.