Abstract
Control of cell adhesion to synthetic polymers is a key factor in tissue engineering. The bioactivity of NiTi after laser melting was investigated implementing in vitro techniques for studying mesenchymal stem cell (MSC) responses. The effects of physical (surface roughness and topography) and chemical (surface Ti/Ni ratio) modifications as a consequence of laser melting on the cell morphology and cell coverage were studied. The results indicate that MSC morphology was affected primarily by topographical factors. No toxic effect in terms of Ni release affected the MSCs, as evidenced by the adhesion and spreading of the cells.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.