Abstract

Urban populations in Morocco receive free medical drugs as prescribed by doctors in district health centres. To explore the exposure pathway of 238U and 232Th and their decay products on the skin of patients, these radionuclides were measured in various medical drugs by using solid-state nuclear track detectors (SSNTDs).The measured concentrations range of 238U and 232Th in the medical drug samples of interest vary from (4.3 ± 0.3) to (11.1 ± 0.7) mBq l−1 and (0.49 ± 0.03) to (1.3 ± 0.1) mBq l−1, respectively. A new dosimetric model, based on the concept of specific alpha-dose and alpha-particle residual energy, was developed for evaluating radiation doses to skin following the application of different medical drugs by patients. The maximum total equivalent effective dose to skin due to the 238U and 232Th series from cutaneous application of different medical drugs by patients was found to be 2.8 mSv year−1 cm−2.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.