Abstract

BackgroundPositron emission tomography (PET) is poised to become a useful imaging modality in staging and evaluating therapeutic responses in patients with metastatic pancreatic cancer (mPC). This analysis from a phase 1/2 study examined the utility of early PET imaging in patients with mPC treated with nab-paclitaxel plus gemcitabine.MethodsTumors were measured by [18F]2-fluoro-2-deoxyglucose PET/computed tomography (CT) in patients who received nab-paclitaxel 100 (n = 13), 125 (n = 38), or 150 (n = 1) mg/m2 plus gemcitabine 1000 mg/m2 on days 1, 8, and 15 of a 28-day cycle. Lesion metabolic activity was evaluated at baseline and 6 and 12 weeks postbaseline.ResultsFifty-two patients had baseline and ≥1 follow-up PET scan. The median maximum standardized uptake values per pancreatic lesion in the nab-paclitaxel 100 mg/m2 and 125 mg/m2 cohorts were 5.1 and 6.5, respectively. Among patients who had a metabolic response by PET, those who received nab-paclitaxel 125 mg/m2 had a 4-month survival advantage over those who received 100 mg/m2. All patients in the nab-paclitaxel 125 mg/m2 cohort experienced an early complete metabolic response (CMR; 34%) or partial metabolic response (PMR; 66%). In the nab-paclitaxel 125 mg/m2 cohort, investigator-assessed objective response rates were 77% and 44% among patients with a CMR and PMR, respectively, with no correlation between PET and CT response (Spearman rs = 0.22; P = 0.193). Patients in the nab-paclitaxel 125 mg/m2 cohort with a CMR experienced a significantly longer overall survival vs those with a PMR (median, 23.0 vs 11.2 months; P = 0.011), and a significant correlation was found between best percentage change in tumor burden by PET and survival: for each 1% decrease in PET score, the risk of death decreased by 2%.ConclusionsThe majority of primary pancreatic tumors and their metastases were PET avid, and PET effectively measured changes in tumor metabolic activity at 6 and 12 weeks. These results support the antitumor activity of nab-paclitaxel 125 mg/m2 plus gemcitabine 1000 mg/m2 for treating mPC and the utility of PET for measuring treatment response. Treatment response by PET analysis may be considered when evaluating investigational agents in mPC.Trial registrationNCT00398086.

Highlights

  • Positron emission tomography (PET) is poised to become a useful imaging modality in staging and evaluating therapeutic responses in patients with metastatic pancreatic cancer

  • A significant correlation was observed between best percentage of change in tumor burden by PET, evaluated as a continuous variable, and overall survival (OS); namely, for each 1% decrease in PET Standardized uptake values (SUV), the risk of death decreased by 2%

  • The results described here support the previously reported survival benefit and antitumor activity of the nab-paclitaxel 125 mg/m2 plus gemcitabine 1000 mg/m2 regimen for treating metastatic pancreatic cancer (mPC) [17, 22]

Read more

Summary

Introduction

Positron emission tomography (PET) is poised to become a useful imaging modality in staging and evaluating therapeutic responses in patients with metastatic pancreatic cancer (mPC). This analysis from a phase 1/2 study examined the utility of early PET imaging in patients with mPC treated with nab-paclitaxel plus gemcitabine. Based on the positive findings of the phase 3 MPACT trial, nab-paclitaxel plus gemcitabine was approved for the first-line treatment of mPC [17, 18] These findings are encouraging, effective PC treatment remains a major challenge, and there is a need to identify those patients who are most likely to benefit from specific therapies

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.