Abstract
AbstractThree‐dimensional infrared emission characteristics of a weak discharge in reset period and two different discharge modes in address period were investigated with 3‐D test panel. Based on 3‐D infrared emissions measured in reset period, the infrared from the cathode were not observed all during the rising and falling ramp reset period and these characteristics are closely related to the electron energy near the cathode. Based on the front and side images of the weak discharge in reset period, the address discharge mode is estimated and experimentally confirmed with the 3‐D test panel. In addition, depending upon various driving conditions, two address discharge modes (single‐tail and double‐tail modes) were observed and discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.