Abstract

In this paper, the results of a 2.88 MW solid state long pulse modulator, which has been designed for the new linear collider at the european spallation source in Lund, are summarized. The presented modulator generates an output voltage pulse of 115 kV with a pulse length of 3.5 ms. The modulator design is verified by measurements performed with a full scale prototype, which is operated under nominal load conditions. All specifications are well within the given limits and the system achieves a pulse efficiency of 96.78% and an overall system efficiency of 91.88%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.