Abstract

The algorithm of operation of MCP1253 charge pump converter in buck mode is studied for the first time by detailed measurements of ripples of output voltage and flying capacitor voltage. Some experimental results for MCP1253 operation in regulation buck mode at combinations of input voltage 5.1 V and output voltage 3.5 V, input voltage 5.1 V and output voltage 4.8 V and input voltage 2.2 V and output voltage 1.7 V for the range of load current from 2 to 100 mA are presented as examples. Realized investigations revealed that algorithm of MCP1253 operation in buck mode, described by its manufacturer, is not defined the all different cases of its use. The algorithm depends on the ratio between input and output voltages, their values and load currents.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.