Abstract
Optimal transducer positions are important as much as the control algorithms and hardware performance in the active noise control system. This study is similar to the past researches on the optimal transducer locations but with a far field noise source having a plane wave characteristic and the noise coming through an opening such as a window in an enclosure. Optimization techniques are used to find sets of optimal loudspeaker positions from a larger possible loudspeaker positions. Loudspeakers are placed on the surface of opening at the wall and inside of the enclosure. Using the measured acoustic transfer impedances and numerical simulations with the optimization technique, optimal positions are identified and compared. When a small number of loudspeakers are used. loudspeaker positions on the opening near the center seems to be the best place, but when a larger number of loudspeakers are used it was difficult to find simple patterns in the optimal positions. With the optimally positioned loudspeakers, optimal microphone positions are also studied.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the Korean Society for Noise and Vibration Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.