Abstract

The purpose of this study is to clarify the effect of energy saving and environmental improvement of the window applying the gelled PCM with elastomer. The gelled PCM is possible to solve a technical problem because of that characteristic properties. According to the experimental results, the light transmittance in the solid and the liquid phase shows 0.1 and 0.6[-]. The heat transmission coefficient of this window is about 6[W/m2/K] at the minimum. When the PCM window installed experimental housing, temperature fluctuation was reduced about 5[K] and the average reduction rate of energy consumption is 13.4[%], and 28.7[%] in maximum.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.