Abstract
Wired monitoring systems have been used for damage detection and dynamic analysis of large structures(bridges, dams, plants, etc.). However, the real-world applications still remain limited, mainly due to time and cost issues inherent to wired systems. In recent years, an increasing number of researchers have adopted WSN(wireless sensor network) technologies to the field of SHM(structural health monitoring). Accurate time synchronization is most critical for the wireless approach to be feasible for SHM purpose, along with sufficient wireless bandwidth and highly precise measuring resolution. To satisfy technical criteria stated above, a wireless vibration monitoring system that uses high-precision MEMS(micro-electro-mechanical system) sensors and A/D convertor is discussed in detail. It was found experimentally that the level of time synchronization fell within <TEX>$200\;{\mu}sec$</TEX>.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Transactions of the Korean Society for Noise and Vibration Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.